Nine Mile Point Nuclear Generating Station
| Company type | Nuclear power plant |
|---|---|
| Industry | Energy |
| Founded | 1969 |
| Headquarters | Scriba , United States |
Area served | New York, United States |
| Products | Electricity generation |
| Owner | Constellation Energy (Unit 1 fully, 82% of Unit 2), Long Island Power Authority (18% of Unit 2) |
| Parent | Constellation Energy |
Nine Mile Point Nuclear Station is a nuclear power plant situated in Scriba, New York, approximately five miles northeast of Oswego along the shore of Lake Ontario. This location also accommodates the James A. FitzPatrick Nuclear Power Plant.
In April 2011, Exelon, headquartered in Chicago, revealed its intention to acquire Constellation Energy, the entity owning and operating Nine Mile Point. Following approval from FERC, the merger was finalized on March 12, 2012, with Constellation adopting the Exelon brand. However, in 2022, Exelon separated its generation assets back into Constellation Energy. Currently, Constellation holds full ownership of Unit 1 and an 82% stake in Unit 2, while the Long Island Power Authority owns the remaining 18%. Both Units 1 and 2 are operated by Constellation and utilize boiling water reactor (BWR) technology.
Units 1 and 2
The two reactors are General Electric-designed boiling water reactors (BWR). Unit 1 is a BWR-2 model (Generation 2) that commenced operations in 1969 with a capacity of , making it the longest-serving commercial nuclear reactor in the United States. Unit 2, classified as a BWR-5, has been operational since 1988 and has a generating capacity of 1,375 MW. Initially commissioned by Niagara Mohawk Power Corporation, ownership remained with them until the plants were sold to Constellation in 2001.
On October 31, 2006, the Nuclear Regulatory Commission extended the operating licenses by 20 years: Unit 1's license now runs through 2029, while Unit 2's extends until 2046.
Unit 2 features a cooling tower standing at 543 feet tall, visible from nearly 30 miles away near Chimney Bluffs, New York. In contrast, Unit 1 cools directly using water from Lake Ontario and does not possess a cooling tower.
In May 2011, General Electric alerted the plant operator about possible calculation errors that might have led to reactor fuel temperatures exceeding expected safety margins.
In 2016, then-Governor of New York Andrew Cuomo instructed the Public Service Commission to evaluate subsidies funded by ratepayers aimed at supporting nuclear plants’ financial viability amid competition from natural gas sources. This directive excluded the Indian Point facility.
Withdrawn unit 3 proposal
Unistar Nuclear, a partnership between Constellation Energy and Électricité de France (EDF), announced plans in late 2008 to file a combined construction and operating license (COL) application for a European Pressurized Reactor (EPR) at the Nine Mile Point site owned by Constellation Energy. Within a year, Unistar requested a temporary halt to the application review process and ultimately withdrew the application in 2013 due to the absence of federal loan guarantees.
Electricity production
| Year | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | Total Annual Generation | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2001 | 1,309,751 | 1,082,371 | 996,634 | 792,703 | 839,639 | 1,213,015 | 1,042,234 | 1,165,283 | 1,233,386 | 1,197,046 | 1,259,445 | 1,098,455 | 13,229,962 | ||||||||||||
| 2002 | 1,301,564 | 1,183,386 | 857,629 | 772,513 | 1,226,472 | 1,250,520 | 1,272,099 | 1,255,248 | 1,243,747 | 1,260,796 | 888,453 | 730,464 | 13,242,891 | ||||||||||||
| 2003 | 1,318,106 | 1,086,660 | 1,037,882 | 838,868 | 1,219,947 | 1,226,521 | 1,068,496 | 1,016,544 | 1,244,842 | 1,288,636 | 1,221,228 | 1,298,812 | 13,866,542 | ||||||||||||
| 2004 | 1,132,313 | 1,174,594 | 791,970 | 495,639 | 1,249,267 | 1,236,082 | 1,282,314 | 1,248,743 | 1,163,039 | 1,268,515 | 1,271.877 | 1.287.183 | 13.601.536 | ||||||||||||
| 2005 | 1.317.483 | 1.188.926 | 1.101.125 | 826.387 | 1.214.595 | 1.232.033 | 1.264.159 | 1.237.864 | 1.235.761 | 1.303.254 | 1.271.780 | 1314381 | 14.507.748 | ||||||||||||
| 2006 | 1311929 | 1157117 | 845319 | 884828 | 1305932 | 1181231 | 1278746 | 1279037 | 1253733 | 1302056 | 1268169 | 1316237 | 14.384.334 | ||||||||||||
| 2007 | 1317419 | 1153677 | 826238 | 1032859 | 1218774 | 1246426 | 1276739 | 1244518 | 1208667 | 1291728 | 847849 | 1299130 | 13.964.024 | ||||||||||||
| 2008 | 1316569 | 1225699 | 1037712 | 787827 | 1297804 | 1237640 | 1268441 | 1279355 | 1243369 | 1232911 | 1150627 | 1309769 | 14.387.723 | ||||||||||||
| 2009 | 1316673 | 1169505 | 1129488 | 1083746 | 1309346 | 1255222 | 1286215 | 1277742 | 1249653 | 1253744 | 1268150 | 1315012 | 14.914.496 | ||||||||||||
| 2010 | 1185280 | 1167767 | 1312218 | 494373 | 1189133 | 1243776 | 1279385 | 1285670 | 1249015 | 1298050 | 1214643 | 1319743 | 14.239.053 | ||||||||||||
| 2011 | 1310649 | 1178658 | 1120852 | 941175 | 1048935 | 1258797 | 1275745 | 1093570 | 1247499 | 1305602 | 1272676 | 11014611 | 14.155.619 | ||||||||||||
| 2012 | 1316184 | 1130245 | 1304973 | 658199 | 461139 | 881195 | 1154809 | 13875219 | 1275120 | 1351902 | 961481 | 1282495 | 13.165.263 | ||||||||||||
| 2013 | 1435237 | 1289866 | 14333011 | 1131870 | 1163963 | 13687311 | 13447411 | 13968201 | 13588151 | 14159311 | 13277191 | 11793391 | 15.846333 | ||||||||||||
| 2014 | 1415857 | 1288293 | 959694 | 486946 | 1360306 | 1344023 | 1402344 | 1398963 | 1347028 | 1420433 | 1386105 | 1429188 | 15.239180 | ||||||||||||
| 2015 | 1432717 | 1123379 | 1166683 | 11948511 | 1410404 | 1366225 | 1396404 | 1387647 | 1284343 | 1427155 | 13861811 | 1422087 | 15.998076 | ||||||||||||
| 2016 | 1434258 | 13391411 | 14260351 | 754831 | 1245904 | 13620141 | 13906601 | 13886181 | 13564871 | 14109251 | 11524241 | 12390751 | 15.500372 | ||||||||||||
| 2017 | 1387866 | 12126791 | 11714431 | 12962981 | 14192871 | 13617091 | 13656721 | 12692401 | 13131581 | 14081171 | 13616251 | 14257861 | 15.992880 | ||||||||||||
| 2018 | 14254221 | 12841091 | 13648051 | 888698 | 900404 | 12904091 | 13863021 | 12950571 | 13459351 | 14070261 | 13748311 | 14198321 | 15.382830 | ||||||||||||
| 2019 | 14233641 | 12578911 | 11490661 | 926790 | 13283621 | 13643041 | 13887991 | 13885381 | 14360641 | 13704961 | 13681691 | 14195331 | 15.821376 | ||||||||||||
| 2020 | 14280831 | 12831071 | 567783 | 12238201 | 14233231 | 13611611 | 13838811 | 13845091 | 13560531 | 14150701 | 13822241 | 14315941 | 15.640608 | ||||||||||||
| 2021 | 14339881 | 12745121 | 12560941 | 12013831 | 14119351 | 13520441 | 13937581 | 13739781 | 13530741 | 13872251 | 13543431 | 14140581 | 16.206392 | ||||||||||||
| 2022 | 14108941 | 11864091 | 701970 | 12246821 | 13990411 | 13459471 | 13751761 | 13675151 | 951058 | 14069441 | 13701381 | 14210571 | 15.790831 | ||||||||||||
| 2023 | 14044441 | 12232761 | 10810051 | 10441501 | 14029441 | 13488181 | 13667131 | 13762291 | 11435311 | 13754471 | 13477641 | 13925801 | 15.506901 | ||||||||||||
| 2024 | 13955211 | 12990251 | 655002 | 13673271 | 14041581 | 13471681 | 13764911 | 13813491 | 11802941 | 13977571 | 13134741 | 13669771 | 15.484543 | ||||||||||||
| -- Data for upcoming years is incomplete -- |
Surrounding population
The Nuclear Regulatory Commission identifies two distinct emergency planning zones around nuclear facilities: a 10-mile plume exposure pathway zone, which concentrates on airborne radioactive hazards, and a 50-mile ingestion pathway zone, which addresses the risk of consuming contaminated food and beverages.
As of 2010, the number of residents living within a 10-mile radius of Nine Mile Point was 35,632, representing a 17.0% rise compared to the previous ten years. Within a 50-mile radius, the population totaled 909,523, reflecting a 3.2% growth since 2000. Notable urban centers in this area include Syracuse, located approximately 36 miles away.
1991 site area emergency
On August 13, 1991, Nine Mile Point declared a "site area emergency" (SAE) following an electrical malfunction that momentarily disrupted power to the reactor and control room. At that time, this event was only the third SAE ever declared at a U.S. nuclear facility.
The issue originated in phase B of Unit 2's main power transformer, which caused the main generator, turbine, and reactor to trip. This voltage drop led to the failure of five Non-Class 1E uninterruptible power supplies (UPS), whose backup batteries had deteriorated due to age. Consequently, critical systems such as control room annunciators, safety parameter displays, control rod position indicators, plant process computers, and communication equipment were compromised.
Despite these obstacles, plant operators executed a safe reactor shutdown in accordance with emergency procedures. The facility achieved cold shutdown status roughly 13 hours after the event, and the SAE was lifted about one hour thereafter. There were no injuries or radiation leaks reported.
Seismic risk
According to a 2010 NRC assessment, the annual probability of an earthquake causing core damage at Nine Mile Point is estimated at 1 in 238,095 for Reactor 1 and 1 in 178,571 for Reactor 2.
See also
- Darlington Nuclear Generating Station—located on the opposite shore of Lake Ontario
- New York energy law
- Nuclear Power 2010 Program
- Pickering Nuclear Generating Station—situated across Lake Ontario
- R. E. Ginna Nuclear Power Plant—approximately 50 miles west near Rochester